Aquacros® HC-2090 is a high-performance liquid blended phosphate product designed to sequester iron and manganese, as well as hardness salts, while also providing corrosion control. It reduces the build-up of scale in the distribution system, helps to prevent the need for replacing existing piping and associated equipment caused by excessive deposition or under-deposit corrosion, and assists municipalities in meeting the Lead and Copper Rule. It is a clear liquid.

Functions: Corrosion Inhibitor, Scale Inhibitor, Sequestering Agent

Chemical Family: Phosphates

Applicable Processes: Drinking Water Treatment, Water Treatment

Features: Corrosion Resistance, Improved Equipment Longevity, Low Operating Cost, Reduces Maintenance Cost, Scale Inhibiting

Ask Harcros Chemicals Inc. Questions

Jared Reigle avatar

MN

Samer Saba avatar
  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Features & Benefits

Industrial Additives Features
Aquacros® Phosphate Blends Features and Benefits
  • Reduced build up of scale in the distribution system.
  • Reduction of replacing existing piping and associated equipment attributed to excessive deposition or under-deposit corrosion.
  • Assists municipalities in meeting the Lead and Copper Rule.
  • NSF/ANSI Standard 60 approved for drinking water.
  • Produces a tight protective coating on metal surfaces, prolonging the life of the system’s equipment.
  • Blended poly/ortho phosphate products allow for sequestering and corrosion control. Zinc/ortho phosphate blends provide excellent corrosion control in very aggressive water systems and are extremely effective for galvanic corrosion control in mixed metal systems
  • These products can remove old scale and corrosion deposits throughout the system which will lower maintenance, operating and equipment replacement costs
  • The Aquacros products create a tight protective coating on metal surfaces throughout the distribution system
  • Usage of Aquacros assists municipalities in meeting the 1991 EPA Lead and Copper Rule, by reducing lead and copper leaching and pipe corrosion
  • ANSI/NSF Standard 60 approved for drinking water
  • Aquacros products can be used in conjunction with Harcros’ family of specialty water chemicals to provide complete protection and optimal performance of any water system

Applications & Uses

Markets
Applications
Applicable Processes
Use Level
max. 23 mg/l (for drinking water treatment)
Preparation and Feeding Information

Aquacros® HC-2090 may be fed directly from the container. A dose of 2.2 gallons of Aquacros® HC-2090 per million gallons of water will achieve a 1.0 ppm total ortho phosphate treatment level.

Properties

Physical Form
Appearance
Clear liquid
Typical Properties
ValueUnitsTest Method / Conditions
Poly/Ortho Blend90:10
Specific Gravity1.32 - 1.39--
Density11.5lbs/gal-
pH (Neat)5.3 - 5.8--
Total Phosphate35.0%-
Phosphate Ion Content33 - 37 %