Enhanced TDS
Identification & Functionality
- Chemical Family
- Industrial Additives Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Industrial Additives Features
- Advantages
- Reduced build up of scale in the distribution system.
- Reduction of replacing existing piping and associated equipment attributed to excessive deposition or under-deposit corrosion.
- Assists municipalities in meeting the Lead and Copper Rule.
- NSF/ANSI Standard 60 approved for drinking water.
- Produces a tight protective coating on metal surfaces, prolonging the life of the system’s equipment.
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Use Level
- max. 23 mg/l (for drinking water treatment)
- Preparation and Feeding Information
Aquacros® HC-2075 may be fed directly from the container. A dose of 2.2 gallons of Aquacros® HC-2075 per million gallons of water will achieve a 1.0 ppm total ortho phosphate treatment level.
Properties
- Physical Form
- Appearance
- Clear Liquid
- Typical Properties
Value Units Test Method / Conditions Poly/Ortho Blend 70:30 Specific Gravity 1.36 - 1.42 - - Density avg. 11.6 lbs/gal - pH (at 1% Solution) 5.5 - 6.5 - - Total Phosphate 35.0 % - Phosphate Ion Content 33 - 37 %
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
- NSF Approval
Aquacros HC-2075 is approved under NSF/ANSI 60 for drinking water treatment.
Packaging & Availability
- Supplied by