Enhanced TDS
Identification & Functionality
- Chemical Family
- Industrial Additives Functions
- Technologies
- Product Families
Features & Benefits
- Industrial Additives Features
- Advantages
- Reduced build up of scale in the distribution system.
- Reduction of replacing existing piping and associated equipment attributed to excessive deposition or under-deposit corrosion.
- Assists municipalities in meeting the Lead and Copper Rule.
- NSF/ANSI Standard 60 approved for drinking water.
- Produces a tight protective coating on metal surfaces, prolonging the life of the system’s equipment.
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Use Level
- max. 18 mg/l (for drinking water treatment)
- Preparation and Feeding Information
Aquacros® HC-2050 may be fed directly from the container. A dose of 2.2 gallons of Aquacros® HC-2050 per million gallons of water will achieve a 1.0 ppm total ortho phosphate treatment level.
Properties
- Physical Form
- Appearance
- Clear Liquid
- Typical Properties
Value Units Test Method / Conditions Poly/Ortho Blend 50:50 Specific Gravity 1.35 - 1.41 - - Density avg. 11.5 lbs/gal - pH (at 1% Solution) 5.2 - 6.2 - - Total Phosphate 35.0 % -